Tia Portal V17 Hsp New Guide

TIA Portal V17 , Hardware Support Packages (HSP) are essential for integrating new Siemens hardware and firmware that were not originally part of the software's base release. For V17 specifically, these updates allow engineers to use newer modules like the ET 200SP TM PTO 2x24V or updated firmware for Key Hardware Added in V17 HSPs

Recent updates for V17 have introduced support for several critical modules: : Adds the SIMATIC ET 200SP, TM PTO 2x24V : Supports the ET 200SP AI RTD/TC HF with Firmware Version 2.1. : Updates the hardware catalog for SCALANCE X200 with Firmware 4.6. : Introduces support for the SIMATIC IPC477E PRO : Adds the ET 200SP F-TM ServoDrive/StepDrive (Firmware 2.0). Siemens SiePortal How to Install V17 HSPs

You can update your V17 hardware catalog through two primary methods:

How do you update the hardware catalog in TIA Portal? - Support

New Hardware Support Packages (HSP) for TIA Portal V17 Keep your engineering environment up to date! Siemens has released new Hardware Support Packages (HSPs) for TIA Portal V17, allowing you to integrate the latest modules and firmware versions into your hardware catalog. What’s New in the Latest Updates?

The most recent additions for V17 include support for specialized modules and updated firmware:

SIMATIC ET 200SP Modules: New support for TM PTO 2x24V (HSP0341) and AI RTD/TC HF FW-Version 2.1 (HSP0357).

Drive & Motion: Updated SIMATIC MICRO-DRIVE PDC(F) (HSP0198 V2.0) and ET 200SP F-TM ServoDrive/StepDrive (HSP0311).

Industrial Computing: Support for SIMATIC IPC477E PRO (HSP0424).

Networking & I/O: New packages for SCALANCE SC600 FW 3.1 (HSP0405) and ET 200eco PN TM PosInput 2 (HSP0409). How to Get the Latest HSPs You can update your catalog using two main methods:

How do you update the hardware catalog in TIA Portal? - Support

To update your TIA Portal V17 Hardware Support Packages (HSP) tia portal v17 hsp new

, you need to download the specific files from the Siemens support site and integrate them into your hardware catalog. This process allows you to configure new modules or firmware versions not included in your original installation. 1. Download New HSPs

You can obtain the latest support packages directly from the Siemens Industry Online Support (SIOS) portal. Direct Download : Visit the Support Packages for TIA Portal (HSP) Siemens SiePortal Version Selection : Ensure you download the package specifically labeled for TIA Portal V17 . The files typically have a extension. Extract Files

: If the download is a ZIP archive, extract the files to a local folder on your engineering station. 2. Install via TIA Portal Software Once you have the files, follow these steps to import them: Open TIA Portal : Launch the software but do open a specific project yet (or close any active projects). Access Settings : Go to the menu and select Support Packages Add from System : Click the "Add from file system" Select Files

: Browse to the folder where you extracted the HSP files, select the required files, and click

: In the "Detailed information" list, select the packages you just added and click

Note: You must close all TIA Portal instances before the installation can finish. 3. Alternative: Use TIA Administrator / Updater

If you have an active internet connection on your engineering PC, you can automate this: TIA Administrator Totally Integrated Automation UPDATER Navigate to the Support Packages "Check for updates" "Find Support Packages" Select the new HSPs from the list and click "Download and install" Troubleshooting & Tips Restart Required

: After manual installation, you must restart TIA Portal for the new hardware to appear in the hardware catalog. Legacy Versions

: If you are working with older hardware, check if you need the HSP for STEP 7 V5.x System Compatibility : TIA Portal V17 is officially supported on Windows 10

. If you are using Windows 11, ensure you have installed the latest V17 Updates (e.g., Update 5 or 6) for better stability. Industrial Monitor Direct specific module

(like a new S7-1500 CPU or ET 200SP head module) that isn't showing up in your catalog? TIA Portal V17 , Hardware Support Packages (HSP)

How do you update the hardware catalog in TIA Portal? - ID: 54163658


References

  1. Siemens AG. (2022). TIA Portal V17 Engineering System – Online Help, Chapter 8: Hardware Support Packages.
  2. Siemens Industry Online Support. (2023). HSP for SIMATIC S7-1200 FW 4.6 – Release Notes, Entry ID: 109817234.
  3. Berger, H. (2021). Automating with SIMATIC S7-1500, 3rd ed. Publicis Publishing. (Relevant chapter on device integration).
  4. Siemens Digital Industries. (2022). White Paper: Managing Hardware Changes in TIA Portal Using HSPs, Document V17.1.0.

Note: This paper is for educational and technical documentation purposes. Actual HSP numbers and exact device support should be verified against Siemens’ official release notes for TIA Portal V17.

TIA Portal V17 HSP: Your Guide to the Latest Hardware Support Packages

The Totally Integrated Automation (TIA) Portal V17 remains a cornerstone for industrial automation, but its effectiveness depends on keeping your hardware catalog current. Hardware Support Packages (HSPs) are essential software components that allow you to integrate new devices and firmware versions that were not included in the original V17 installation. What is a TIA Portal V17 HSP?

An HSP (Hardware Support Package) is a specific update file—typically with the .isp17 extension for Version 17—that adds new modules, CPUs, or network components to your hardware catalog. Without these updates, you may find yourself unable to select the latest Siemens hardware in your project view, even if the physical device is sitting on your desk. Recent Key HSPs for V17

As of mid-2025, Siemens continues to release updates to ensure V17 users can leverage modern hardware. Notable recent additions include: HSP0398: Support for SCALANCE X200/X300 with Firmware 4.6. HSP0405: Integration for SCALANCE SC600 (FW 3.1).

HSP0416/HSP0435: New modules for SIMATIC ET 200SP and ET 200pro. HSP0453: Support for the SIMATIC S7-1500 TM MFP (FW 1.1). How to Install New HSPs in V17

You can update your catalog using two primary methods provided by Siemens: 1. Automatic Update (Recommended)

If your engineering station has internet access, use the TIA Software Updater:

Navigate to Start > All Programs > Siemens Automation > Totally Integrated Automation UPDATER.

Go to the Support Packages tab and click Find Support Packages. References

Select the required updates and click Download and install selected packages. 2. Manual Installation

For offline machines, you must download the files manually from the Siemens Industry Online Support (SIOS) portal (Entry ID: 72341852).

Download & Unpack: Download the .zip file for V17 and extract it to a local folder.

Add to TIA Portal: Open TIA Portal V17 and go to Options > Support packages.

Import: Click Add from file system, navigate to your extracted .isp17 files, and click Open.

Install: Select the packages marked "No" in the "Installed" column and click Install.

Finalize: Close all TIA Portal windows when prompted to allow the installer to complete the process. Critical Tips for V17 Users

Why does the installation of an HSP for TIA Portal end with an error?

When you see "HSP New" in the context of TIA Portal, it generally refers to adding support for newer Siemens hardware devices (like the latest S7-1200 CPUs, HMI panels, or Drives) to an older version of the TIA Portal software. Since TIA Portal V17 is not the newest version, you will almost certainly need to install HSPs to use hardware released after V17 launched.


1. Introduction

Industrial automation projects often face a conflict: new hardware becomes available, but the engineering software is locked to a specific version. Prior to HSPs, supporting a new CPU required updating the entire TIA Portal installation. With V17, Siemens expanded the HSP mechanism to cover a wider range of devices, including SIMATIC S7-1500, S7-1200, SINAMICS drives, and even ET 200SP distributed I/O. This paper focuses on the new HSPs introduced alongside TIA Portal V17 and their impact on engineering efficiency.

Example Snippet (conceptual)

  • Use the new HSP_Capture block to timestamp encoder pulses, store in a circular buffer, then have a lightweight cyclic task read and process buffer entries for analytics—minimizing CPU load while preserving microsecond timing accuracy.