The Siruba L818-M1 (part of the L818 series) is an industrial high-speed single-needle lockstitch machine. While there isn't a specific "2021-only" error list, these machines use a standard set of electronic control error codes found in their technical manuals. Common Error Codes (E / ERR List)

Electronic errors usually flash on the control panel display. Error Code Likely Cause / Solution E1 / ERR19 Over Voltage Power voltage is too high. E2 / ERR20 Low Voltage

Power voltage is too low or power supply capacity is too small. E3 / ERR15 Motor Locked The machine or motor is physically jammed. E4 / ERR1 Encoder / Pattern Error

Issue with the motor encoder connector or data cannot be read. E7 / ERR3 Needle Position Error Needle bar is not in the correct position. ERR17 Emergency Switch The emergency stop switch has been pressed. ERR34 Power Off System has detected a power-down state. Key Features of the L818-M1

High Speed: Capable of speeds up to 5,000 stitches per minute.

Automatic Functions: Includes programmable back-tacking and automatic thread cutting (scissor function).

Versatility: Designed for light to medium fabrics like bridal wear and curtains.

Adjustability: Features a rotary stitch size selector (0–5mm) and a built-in knee lift for the presser foot (up to 13mm). Troubleshooting Tips

Hard Reset: For computerized errors, try turning the machine OFF and ON again to clear temporary glitches.

ER01 Fix: If you see ER01 on a brushless motor, it often means the needle positioning system is active but not plugged in. siruba+l818fm1+error+list+2021

Manual References: For detailed parameter adjustments, you can refer to the official Siruba Electronic Control Manual or the L818F Instruction Manual .

Are you currently seeing a specific error code on your machine's display that you need help clearing? Electronic control parameter manual - SiRUBA Sewing Machine


4. E-045 (Safety Switch Activation) – False Trigger

The magnetic safety switch on the looper cover door is prone to magnet misalignment after repeated opening/closing. Fix: Glue a small neodymium magnet (5mm x 2mm) onto the door’s existing magnet to strengthen the signal.

Immediate Steps for Any Error

  1. Power cycle the machine (turn off for 10 seconds, then restart).
  2. Check all connectors between control box, motor, and panel.
  3. Clean the machine thoroughly – fluff and lint trigger false errors.
  4. Manually rotate handwheel to ensure no mechanical seizure.

3. Data fields in the error list (for 2021 models)

Siruba L818FM1 Error List 2021: The Complete Troubleshooting Guide for Industrial Overlock Machines

1. Error Code Table (common codes for 2021 firmware)

| Error Code | Message | Possible Cause | User Action | |------------|---------|----------------|--------------| | E-01 | Motor overload | Thread tangled, material jam | Remove fabric/thread, restart | | E-03 | Needle position sensor error | Sensor dirty/misaligned | Clean sensor, recalibrate | | E-05 | Foot lift solenoid failure | Solenoid stuck or disconnected | Check wiring, replace solenoid | | E-07 | Thread trimmer error | Knife stuck, magnet switch fault | Clean trimmer mechanism | | E-08 | Low voltage (under 180V) | Power supply unstable | Check mains voltage | | E-10 | Main motor encoder fault | Encoder disconnected/damaged | Replace encoder board | | E-12 | Control panel communication lost | Cable loose or panel faulty | Reconnect panel cable | | E-15 | Overcurrent | Short in motor or driver | Cycle power; if persists, service |

⚠️ Important Note

Siruba’s official 2021 error list may vary slightly depending on the firmware version (e.g., v3.2 or v4.0) installed on the L818F-M1.
If you need the exact 2021 factory error list, I recommend:

Where to find the exact code:

If you see a code not listed above (e.g., E20, E99):

  1. Look at the Control Box: The control box is usually located under the table or inside the machine body. It has a small LED window.
  2. Count the flashes: Some codes are indicated by the number of flashes of the "Ready" light.
  3. Contact your dealer with the Serial Number and the specific Panel Model Number (printed on the front panel circuit board).

Disclaimer: The error codes above are standardized for the Siruba direct-drive lockstitch series. Specific firmware versions installed in 2021 may have minor variations. Always disconnect power before servicing.

Siruba L818F-M1 is a high-speed lockstitch machine that typically uses external electronic control systems like the

or similar. Below is the standard error code list for these systems, covering common issues such as voltage fluctuations, motor locks, and signal failures. SiRUBA Sewing Machine Siruba Common Error Codes (L818 Series) Error Code Description Troubleshooting Steps E1 / ERR19 Over-voltage protection Check if the power voltage is too high for the machine. E2 / ERR15 Motor encoder failure The Siruba L818-M1 (part of the L818 series

Ensure the motor encoder connector is securely inserted; check signal lines (ECA/ECB). Machine or Motor Lock

Check for mechanical obstructions or thread jams in the machine head or motor. E4 / ERR18 Data transmission error

Check motor connector signals and ensure all cables are properly seated. External noise interference

Remove sources of electromagnetic noise or check for high-frequency input signal errors. E8 / ERR17 Position detector error

Check if the UP/DOWN signal detector connector is loose or if signals are broken. Solenoid defect

Inspect solenoid wiring for short circuits or replace the solenoid if defective. 12V Power supply fuse Check and replace the fuse for the +12V power supply. E15 / ERR14 Over-current protection

Inspect the power board for abnormal current; typically requires hardware repair. Machine tip-over switch

Ensure the machine is in the correct upright position and the safety switch is engaged. Additional Resources : You can find detailed technical diagrams in the L818F Parts List Instruction Manual Control Parameters : For advanced motor settings, refer to the Electronic Control Parameter Manual on the official Siruba website. SiRUBA Sewing Machine

Are you seeing a specific error code on your display right now? Electronic control parameter manual - SiRUBA Sewing Machine Power cycle the machine (turn off for 10

Siruba L818FM1 Error List 2021

The Siruba L818FM1 is a type of industrial sewing machine made by Siruba, a well-known manufacturer of textile machinery. The error list for this machine is crucial for technicians, operators, and maintenance personnel to diagnose and troubleshoot issues efficiently.

While I couldn't find an exhaustive error list for the Siruba L818FM1 specifically, I can provide some general information on common errors that may occur in industrial sewing machines like the L818FM1.

Common Errors in Industrial Sewing Machines:

  1. Error Code E01: Usually indicates a problem with the machine's power supply or electrical system.
  2. Error Code E02: Often related to issues with the machine's motor or speed control system.
  3. Error Code E03: Typically associated with problems in the machine's stitch formation or thread tension.

For the most up-to-date and specific error list for the Siruba L818FM1, I recommend:

  1. Consulting the user manual: The best place to start is by checking the machine's user manual or technical documentation, which should provide a comprehensive error list and troubleshooting guide.
  2. Contacting Siruba support: Reach out to Siruba's customer support or technical service department for assistance with error codes and troubleshooting.
  3. Checking online resources: Websites like YouTube, forums, or blogs dedicated to textile machinery and industrial sewing machines may have user-generated content, tutorials, or discussions related to the Siruba L818FM1 error list.

Common Errors with Siruba L818FM1

While I don't have access to real-time data or a specific error list for the Siruba L818FM1 as of 2021, industrial sewing machines like this model can encounter a variety of issues. Here are some common errors or problems that might occur:

  1. Thread Breakage: Frequent thread breakage can be caused by incorrect threading, improper tension, or using the wrong type of thread.

  2. Needle Breakage: Needles can break due to incorrect needle size or type, improper alignment, or sewing over thick parts of the fabric.

  3. Stitch Inconsistencies: Inconsistent stitch lengths or types can be due to issues with the machine's timing, incorrect bobbin tension, or worn-out parts.

  4. Machine Not Feeding Fabric Properly: This issue might arise from incorrect presser foot pressure, damaged feed dogs, or the wrong type of fabric being used.

  5. Electrical or Computerized Errors: For computerized models, errors can range from simple settings issues to more complex motherboard or sensor problems.