FirstChip MpTools does not require a password by default to access its standard configuration or settings menus.
If you are prompted for a password while attempting to access advanced configurations in FirstChip MpTools (used for flashing or repairing FirstChip controllers like the FC1178 or FC1179), it usually indicates that the software has a blank password field, or you are running a specific vendor-modified version.
Below is a complete overview and review of the password system and functionality of FirstChip MpTools. 🔑 The Password System: How It Works Default State:
For most standard, public distributions of FirstChip MpTools, simply leaving the password field completely blank
and clicking "OK" or pressing Enter will grant you full access to the settings. Common Alternative Passwords:
On certain modified builds or specific mass-production packages, developers or vendors may lock settings. If a blank password does not work, the most common defaults across similar mass production tools are The Purpose:
The password prompt functions solely as a safety gate. It is intended to prevent line workers or casual users from accidentally modifying low-level controller parameters—such as block scanning, voltage settings, or firmware bins—which can permanently brick a USB drive. ⚙️ What the Password Unlocks
Once you bypass the password prompt to enter the "Settings" or "Config" panel, you gain access to critical operations: Flash Sorting & Scanning:
You can configure how aggressively the tool scans the NAND flash memory for bad blocks. Firmware Flashing:
It allows you to select and write the specific firmware binary tailored to your FirstChip controller model. Capacity Adjustment:
You can restore the true capacity of a corrupted drive or fake-capacity drive. VID/PID Modification:
You can change the Vendor ID (VID) and Product ID (PID) to make the computer recognize the USB properly. ⚠️ Critical Security & Usage Warnings Data Destruction:
Accessing these settings and running a "Start" or mass production cycle will completely wipe all data
on the USB drive. Mass production tools reset the translator and controller, making prior data impossible to recover using standard software. No User Lockout Feature:
This password is not a security feature to lock your USB drive from unauthorized access. It is exclusively an internal tool feature for the software interface itself. Source Reliability:
Because these tools are leaked or distributed outside of official consumer channels, ensure you download FirstChip MpTools from reputable flash drive repair repositories (like specialized USB developer archives) to avoid malware. find your specific controller model to ensure you are using the correct version of MpTools?
Recovering FirstChip MPTools Password: A Step-by-Step Guide
Are you locked out of your FirstChip MPTools due to a forgotten password? Don't worry; we've got you covered. In this post, we'll walk you through the process of recovering or resetting your FirstChip MPTools password.
What is FirstChip MPTools?
FirstChip MPTools is a popular tool used for managing and configuring FirstChip-based devices. It's essential for optimizing device performance, updating firmware, and troubleshooting issues. However, if you've forgotten your password, it can be frustrating.
Method 1: Default Password
Before attempting to reset your password, try using the default password. The default username and password for FirstChip MPTools are usually: firstchip mptools password
If these credentials don't work, proceed to the next method.
Method 2: Reset Password using the Web Interface
If your device has a web interface, you can reset the password using the following steps:
192.168.0.1 or 192.168.1.1).Method 3: Reset Password using the Console
If the web interface method doesn't work, try resetting the password using the console:
Method 4: Contact FirstChip Support
If none of the above methods work, it's possible that your device has a custom or encrypted password. In this case, contact FirstChip support for assistance:
Conclusion
The default password for FirstChip MPTools (specifically to access the settings or "Setup" menu) is usually blank (leave it empty) or 123456. FirstChip MPTools Review
FirstChip MPTools is a specialized utility designed to repair "dead" or corrupted USB flash drives that use FirstChip controllers (like the FC1178 or FC1179). It is widely considered a "last resort" tool for fixing drives that Windows cannot format or that show a "No Media" error. Quick Breakdown
The Good: Extremely powerful; it can revive drives with firmware errors, bypass write protection, and identify "bad blocks" to make a drive usable again.
The Bad: The interface is technical and "dull," often requiring users to navigate menus that may be in a different language or involve foreign websites for downloads.
The Warning: It is destructive. Running the mass production process erases all data on the drive permanently. Key Features
No Installation Required: You can run it directly from the extracted archive without modifying Windows registries.
Controller Specific: Specifically formats Alcor or FirstChip chip controllers to display accurate storage information.
Customization: Allows you to set a password for the setup window to prevent accidental configuration changes.
Recovery: Highly effective at fixing "Insert Disk" or "Device Not Recognized" errors by re-flashing the firmware.
For a walkthrough on how to use MPTools to fix a broken USB drive, watch this guide:
For FirstChip MPTools, the default password to access the "Settings" or "Setup" menu is typically empty; you can usually simply click "OK" or "确定" (Confirm) without entering any characters. Common Passwords and Access Tips
If an empty field does not work, the following codes are frequently used for mass production tools (MPTools) of this type:
None (Leave Blank): Most FirstChip versions (e.g., FC1178, FC1179) have the password set to empty by default. FirstChip MpTools does not require a password by
123456: A common secondary fallback for many Chinese mass production utilities. 0000: Used in several older MPTool revisions.
320: While more common for SMI (Silicon Motion) tools, it is sometimes attempted for FirstChip variants.
usbdev.ru: Occasionally used as a file-level or archive password if you downloaded the tool from the USBDev website. Accessing the Settings Menu
Identify the Chip: Use a diagnostic tool like ChipGenius to confirm your controller is specifically a FirstChip model (e.g., FC1178BC, FC1179).
Run as Administrator: Ensure you launch the MPTool.exe with administrator privileges to avoid configuration errors.
Language Toggle: Many tools open in Chinese. Look for a "Language" or "English" checkbox on the side panel to make the interface more readable.
Confirm Settings: Once in the Settings menu, you can re-initialize the controller, set the true capacity, and map bad blocks to fix "No Media" or "Write Protected" errors.
Did you receive a specific error code when trying to enter the settings?
The password for FirstChip MpTools is typically left blank by default. To access the settings, you can simply leave the password field empty and click the confirmation button (often labeled "确定" or "OK"). Software Overview & Review
FirstChip MpTools (also known as I-T117x MpTools) is a specialized mass production tool used for low-level formatting and firmware repair of USB flash drives utilizing FirstChip controllers, such as the FC1178 and FC1179 series. Primary Use
Repairing "No Media" errors, corrupted firmware, and fixing fake-capacity drives. Compatibility
Supports FC1178 (AB, BC, E, S) and FC1179 (S, AB) controller variants. Installation
Portable (no installation required); run directly from the .exe file. Interface
Default is Chinese; can be switched to English in the side panel. Pros and Cons FirstChip FC1178/FC1179 MpTools V1.0.5.2 (2022-06-01)
Repairing a corrupted USB drive often feels like a digital archaeology project, especially when dealing with specific controllers like
. If you've found yourself staring at a "0GB" or "No Media" error and downloaded a tool like FirstChip MpTools
, the biggest hurdle is usually the password required to access the deep configuration settings. The Password "Secret"
For most versions of FirstChip MpTools (like the FC1178 or FC1179 variants), the password system is simpler than it looks: The Blank Entry : In many cases, the password field should be left empty
. Simply clicking the confirm button (often labeled with the Chinese characters “确定”) will grant you access to the settings. Common Defaults
: If a blank entry doesn't work, community experts suggest trying standard factory defaults such as Using the Tool Safely
Once you bypass the password prompt, you are in the "engine room" of your flash drive. Here is how a typical repair story unfolds: Identify the Chip : Before running the tool, use a diagnostic utility like ChipGenius Username: admin Password: 123456 or admin
to verify that your controller is indeed a FirstChip. Attempting to flash the wrong firmware can permanently "brick" the device. Run as Administrator MpTools.exe
with administrative privileges to ensure it can communicate directly with the USB hardware. The "Init" Status
: When you plug in your drive, it should appear in one of the tool's ports with an "Init" status. This means the software has detected the hardware and is ready for instructions. Auto-Configuration
: Inside the settings (accessible via the password-protected button), most users find success by selecting the
profile or "Auto size." This allows the software to scan the NAND flash memory, identify "bad blocks," and create a new, functional partition. The Result
: If successful, the tool will wipe the drive and "re-map" it. You might end up with a slightly smaller capacity than what was printed on the case, but you will have a working drive again. Important Warning
: These tools are often unsigned and can be flagged by antivirus software as potential threats. Always download from reputable community hubs like and run them in a secure environment if possible. of MpTools for your chip model?
Most public articles are either clickbait, contain malware, or provide "default" passwords that do not work for newer versions of the software (which use dynamic passwords based on the date).
Here is a breakdown of what you need to know, including how the password system works and how to find the correct one for your specific version.
Step 1: Extract and Run as Administrator
Extract the MPtools ZIP file to a folder on your C: drive (avoid long paths or desktop folders). Right-click MPTools.exe and select Run as Administrator.
Step 2: Face the Password Dialog Immediately, a small window titled “Password” or “Input Password” will appear.
Step 3: Enter the Firstchip MPtools Password
Type 123456 and click “OK” or “Unlock.” If that fails, try 888888, then 000000, then 234567.
Step 4: Access the Main Interface Upon successful entry, the main MPtools window will open. You will see a blank list of ports.
Step 5: Identify the Drive
Insert your problematic USB drive. The tool should detect it in one of the slots (usually “Port 1”). If not, click the magnifying glass icon (“Refresh”) or press F5.
Step 6: Configure the Settings
Press F9 or click “Setting.” Enter the password again (usually the same one). Here you can set:
Step 7: Start Mass Production Click “Start” or “Space Start.” The tool will rewrite firmware, reallocate bad blocks, and format the drive. This takes 2-10 minutes.
Step 8: Success Verification When the status turns from “Pretest” to “PASS” or “Ready,” close the tool, unplug the USB drive, and plug it back in. It should now appear in Windows Explorer with correct capacity.
Is it legal to use Firstchip MPtools? Yes, for repairing your own hardware. However, some counterfeit drive manufacturers use MPtools to fake drive capacity (e.g., making an 8GB chip report 64GB). Using the password to create counterfeit drives for sale is illegal in many jurisdictions and unethical. Always use MPtools for legitimate repair, not fraud.
After years of community reverse-engineering and sharing on forums (like USBDev, MyDigitalLife, and Reddit’s r/datarecovery), the passwords for Firstchip MPtools have become well-documented. There is no universal password—different tool versions and different controller models use different keys.
Here are the most frequently encountered passwords:
| Tool/Controller Version | Typical Password | Alternate |
| ----------------------- | ---------------- | --------- |
| FC1081 MPtools | 123456 | 888888 |
| FC1178 MPtools (common) | 123456 | 000000 |
| FC1179 MPtools | 234567 | 888888 |
| FC2279 MPtools | 123456 | 111111 |
| Generic FC MPtools v5.x | 320 | 123456 |
| Firstchip Sorted Tool | 888888 | 000000 |
The most likely password for recent Firstchip MPtools versions is 123456. If that fails, 888888 and 000000 are the second and third most common.
Important: Some specialized tools (e.g., for USB 3.0 controllers) use a fixed password that cannot be changed, usually
123456. If none of the above works, the tool may be corrupted or require a specific password from the leak source.